Gas chromatography – a key test of purity

‘Are your oils pure?’

It’s something we are often asked, and it’s a great question because there is a lot of adulteration in essential oils which may change their therapeutic properties.

Sometimes the adulteration is deliberate and open because the oil is destined for the chemical or fragrance industry; sometimes it is caused erroneously by, for example, storing the oil in a plastic container; and sometimes it is done with the purpose of deception, ‘cutting’ the oil with a cheap chemical to increase profit.

The more hands that an oil has gone through, the more likely it is that there is some adulteration, which is why it’s always better to source oils direct from the grower. But in all cases the oil needs careful testing.

The most important test is gas chromatography where the components in the oil are analysed and compared to industry standards. Many people are aware of the term but have only a hazy understanding of what it is, so here is a brief technical guide, prepared by our own Nicola Whitehead (Nic has a degree in chemical engineering). She’ll be looking at how it works, what kind of results are obtained and what we can learn from them.

What is GCMS?

GCMS stands for Gas Chromatography and Mass Spectrometry, also sometimes known just as ‘GC’. It is a test carried out on a substance to analyse its constituents by breaking it down so that the different parts can be identified. (Think back to the ink chromatography experiment you did in high school science with the pens and the filter paper – it’s like that but in gas form – hence the name.)

What actually happens?

To begin with the essential oil sample is injected into the GC column along with an inert gas which carries it through the process. Helium, nitrogen, argon and hydrogen are all commonly used gases and the choice of gas is generally related to the equipment being used. The GC column is heated, vapourising the oil into its constituent components. The components then progress through the column at different speeds and exit at different times depending on their boiling point and polarity.

The time from injection to detection is known as the ‘retention time’ and separating the components out allows them to be detected. Popular front-runners in the race include lighter and more easily vapourised components such as pinene and 1,8-cineol (found in oils such as Pine and Eucalyptus) whereas the heavier components found in oils such as Vetiver, Sandalwood and Patchouli can take much longer to be detected.

As a side note, this is why Oshadhi oils are distilled using low temperature and pressure over a longer time period. A gentle extraction method allows time for the least volatile components to come through so that the resulting oil contains the full spectrum of components and therefore therapeutic benefit. Distilling at a higher temperature and pressure takes less time and is therefore more cost-effective but the oil would be all top notes and no substance – a cheap and ephemeral imitation of the real thing.

Once the components are separated they pass into the mass spectrometer where they are broken down into ionised fragments which can be detected electronically. The use of gas chromatography and mass spectrometry together reduces the possibility of mis-identifying the components and increases the accuracy of the results.

What do the results look like?

The test process generates a gas chromatogram which is a graph showing the time taken for each component to exit the and its abundance. Each peak corresponds to an as yet unidentified component and the area under the peak equals the percentage of that component in the sample. It’s not necessary to actually work this out though – thankfully modern test equipment does this for you so no need for a lesson in calculus!

The peaks are identified using a reference library that contains either a full list of possible components or just those of interest. This is why you will sometimes see GCMS results with a long list of components and others with just a few. In some cases the test will only focus on the components that demonstrate the quality and purity of the oil, including those of particular therapeutic benefit and possible adulterants or allergens.

The appearance of the results can vary – for some oils the test results will show the actual output from the analysis software but more commonly these are now translated into an easy-to-read table which shows only the component and the percentage contained in the sample.

The example below shows the generated results including the peak number, retention time, percentage contained in the sample, the library reference to which the peak was compared, the identifying CAS (chemical) number for the component and the quality (certainty) figure for the result.

What can we learn?

The basic result of a GCMS test is a list of components that are contained within the sample and the proportion of each. Interesting… but what does it tell us?

As a supplier the GC can confirm the percentage of certain desirable components in the oil, for example chamazulene in German Camomile oil, and also the percentage of components known to be allergens or sensitisers, which forms a key part of the safety data supplied with each essential oil.

A chromatogram may also show peaks corresponding to components that either shouldn’t be there at all, or that shouldn’t be there in that quantity. An example of this would be the addition of an isolated ‘natural’ component such as limonene or menthol which would show a larger than expected peak in a sample of lemon or peppermint oil.

Each oil has an expected profile and the gas chromatogram can show where a sample deviates substantially from what is expected. It has its limitations though – adulteration by mixing similar oils can give an oil that isn’t authentic but shows a profile that is broadly as would be expected.

Also the tests will give a ‘quality/certainty’ figure, and in some cases the certainty that the data is correct is as low as 86%. This is due to certain components being present with varying isomers (configurations of atoms) and these can be hard to distinguish. For this reason the GCMS test forms only a part of the extensive range of tests that are carried out. Using these tests alongside batch traceability and the more rigorous chain of custody controls of organic certification ensures that oils are supplied not only pure and unadulterated but also authentic – as in, exactly how they came out of the plant.

As a customer it’s more likely that you will use gas chromatography data to help with formulating blends or products. You may need to check the percentage of a particular component to comply with cosmetic safety legislation or to avoid an allergen as part of an aromatherapy consultation. It can also be helpful when choosing oils, especially those that have different chemotypes. Obtaining the GC data for different types of a particular oil can help you to see the differences in chemistry and help you choose the right oil for your requirements. You may also use this data via essential oil libraries such as Dropsmart and Labaroma to create blends or research the properties of essential oils.

Here is a quick explainer:

So, there ends today’s science lesson. As always, if you have any questions please raise your hand!